By Chemist Michael Dawoud Soliman
Ph.D. Researcher in Environmental Chemistry and Biology
Sustainability in tourism requires environmentally conscious management of natural resources, as tourist resorts create seasonal peaks in human pressure on their surroundings. Popular summer holiday destinations are typically arid or semi-arid regions (such as the Mediterranean region) that experience water stress and tourism pressure during the same period. In most cases, large tourist resorts face these problems simultaneously; a joint solution should therefore be sought.
Holiday regions often include naturally sensitive areas far from towns with centralized infrastructure, such as wastewater treatment plants and landfills. For hotels located far from central systems, transporting waste streams becomes a costly operation. The seasonal operation of these resorts prevents the establishment and economical operation of centralized infrastructure. Alongside drinking water, holiday resorts also need water to irrigate their gardens, yet the large quantities of water required for irrigation may pose a problem.
Both irrigation and tourism pressure often occur during the period of minimum or low water resource replenishment, which maximizes potential negative environmental impacts (1). In areas with limited access to freshwater, this pressure is stronger. Given that both resource demand and waste generation are often only seasonal issues, decentralized systems with an integrated approach represent an attractive solution for large tourist resorts.
In this context, an innovative decentralized and modular concept for wastewater treatment, solid waste disposal, and energy production was applied under the MODULAARE research project. The project focused on the practical and economic feasibility of the integrated approach, and the work was carried out by a consortium consisting of:
University of Stuttgart, AT-Verband, MEMOS GmbH, BioSystem Schwarting GmbH, TUI AG, and Mainau GmbH.
The concept was implemented in a large Turkish tourist resort. A pilot plant combining wastewater treatment and solid waste management was installed and operated during the summer seasons. Water use and solid waste generation were determined during the project (2).
The pilot hotel is located in a natural area on the southwestern coast of Turkey and covers 65,000 square meters. It regularly contained 746 beds across 373 rooms. However, capacity expanded to more than 900 beds during peak seasons. The hotel provides restaurants, cafes, swimming pools, a laundry, a health center, some shops, and a small petting zoo for its guests. It was open to guests seasonally, during the seven warmer months of the year. In the so-called “peak season,” about 50 employees lived in the hotel staff accommodation. The hotel was representative of large, all-inclusive 4- and 5-star holiday resorts in the Mediterranean region.
Two different types of water were used at the hotel: drinking water from the municipal network and groundwater. Groundwater was used exclusively for garden irrigation. Drinking water was used in the rooms, kitchen, laundry, swimming pools, and in limited cases also for the garden. Water use in the hotel was determined through existing water meters. The hotel was connected to the municipal wastewater treatment plant (WWTP), which was an advantage for potential technical failures in the pilot plant. Wastewater production was measured on the main pipeline leading wastewater to the municipal wastewater treatment plant.
The membrane pilot plant (MPP) unit was built in a shipping container in Germany and transported to Turkey. Operation was carried out during the three summer months. A portion of the wastewater produced at the hotel (7–10 m³/day) was pumped into the MPP. The wastewater treatment process consists of primary sedimentation, a low-load activated sludge step designed to remove nitrogen and carbonaceous matter, and membrane filtration (Figure 1). For membrane filtration, 6 tubular MEMOS Pulse units with a pore size of 0.2 micrometers and 40 square meters of surface area per unit were used. In the second season, a screen was added before primary sedimentation as large coarse solids appeared in the water flow line to be much higher than design values. Excess sludge from the aeration tank was first pumped into the primary sedimentation tank and then removed along with the primary sludge from the MPP. The treated wastewater permeated through submerged membrane units placed in the aeration tank and was pumped into the hotel irrigation pond after intermediate storage in the MPP.
The treatment efficiency of the MPP was determined by analyzing wastewater parameters in a simple laboratory set up on the hotel grounds for the project. In addition to chemical parameters, sanitary parameters (total coliforms, E. coli, and enterococci) were analyzed.
Total drinking water use at the pilot hotel depends on the hotel occupancy rate. At the start of the summer holiday season, only 10–18% of the hotel’s normal capacity was occupied, and specific water use was very high at 1,500 liters per visitor-day. However, by the third week of the season, guest numbers had already reached 75% of normal capacity, and specific water use dropped to 430 liters per visitor-day. This variance stems from irregular work required only at the start of the season and water needs in facilities such as swimming pool conditions, where water demand does not show a linear relationship with the number of users. When evaluated over six months in each season, excluding the first two or three weeks, specific drinking water use ranged between 330–528 liters per visitor-day. The overall average was 448 liters per visitor-day for all summer seasons, including values at the lowest hotel occupancy. Compared to similar regions and similar hotel types, drinking water consumption at the pilot hotel remained at an acceptable level, and indeed in the lower range (3).
Irrigation water use was determined for two summer seasons. Water use in a given area of the garden correlates with air temperature and precipitation. At the start of the season, the value remained below 100 liters per square meter-month, yet a sharp increase was observed during the first three months. In the so-called peak season from June to August, total precipitation was close to zero, and irrigation water use ranged between 170–190 liters per square meter-month. The seasonal average, taking into account the two estimated summer seasons, was 133 liters per square meter-month. During the investigation period, 25 to 65% of the supplied water returned to the sewage network, though the proportion was mostly more than 50%. Wastewater production also varied with hotel occupancy, resulting in specific values mostly ranging around 200 liters per guest-day. Assuming 900 guests, this corresponds to a monthly wastewater production of 5,400 cubic meters. With this amount of water, at least 30,000 square meters of garden can be irrigated during the driest months when water demand is about 180 liters per square meter-month. For the rest of the summer season with lower irrigation demand, the wastewater can suffice for a garden area of 45,000 square meters.
Certain specific elements are compared with typical domestic wastewater in the table below, with the pilot hotel’s wastewater containing extremely high solids resulting from the discharge of ground food into the drains and causing a COD:N:P-ratio of 170:5:2. Relatively high concentrations of phosphorus were also observed, carried by laundry wastewater. The remaining elements were comparable to typical domestic wastewater.
The average COD effluent concentration over the entire inspection period was 23 milligrams per liter, which corresponds to a 99% COD removal rate. The nitrogen removal rate was about 97%, though it dropped to 91% in the last season to increase the fertilizer quality of the liquid residue. The process could be controlled; however, precise control of effluent nitrogen concentrations was not achieved. Although occasional spikes were also observed, most phosphorus concentrations were measured around 5 milligrams per liter.
The effluent was distinguished by fertilizer quality alongside nitrogen and phosphorus, as potassium and magnesium concentrations were sufficient to cover the turfgrass demand presented by Oral and Acikgöz (4). Heavy metals do not pose an obstacle to the fertilizer properties of the effluent. The sanitary quality of the effluent also pointed to a safe product, as measured values were below the limits given in the European Union directive for bathing and recreational purposes (76/160/EEC) as well as the World Health Organization guidelines given in references (5-6-7-8).
Conclusion
The specific wastewater characteristics in this study differed from typical domestic wastewater in terms of COD and phosphorus. The high chemical oxygen demand concentrations resulted from the disposal of ground kitchen waste into the drains. Effective mechanical treatment in such cases was observed to be essential.
Wastewater treatment through a membrane bioreactor at the pilot hotel was highly effective and produced high-quality wastewater. Chemical and microbiological analyses proved that the treated wastewater is safe to use for recreational purposes. Furthermore, it was distinguished by fertilizer quality given its nitrogen, phosphorus, and potassium content. No harmful content above critical values was detected in the effluent.
References




- Antakyali, D., Krampe, J., Steinmetz, H. (2008). Practical application of wastewater reuse in tourist resorts. Water Sci. and Tec., Vol 57, No 12, pp 2051-2057.
- ATV-DVWK (2000). ATV-DVWK-A 131E, Dimensioning of single-stage activated sludge plants. Gesellschaft zur Förderung der Abwassertechnik e. V, Hennef, Germany
- EC- Technical Report (2007). Mediterranean Water Scarcity and Drought Report, Technical report on water scarcity and drought management in the Mediterranean and the Water Framework Directive. Report Number – 009 – 2007
- Oral, N., Açıkgöz, E. (2002). Çim Alanların Gübrelenmesi. TMMOB Ziraat Mühendisleri Odası Bursa Şubesi Başkanlığı Yayınları, Bursa, Turkey
- WHO (2006). Guidelines for safe use of wastewater, excreta and greywater, Volume 2, wastewater use in agriculture. World Health Organization, Geneva, Switzerland, ISBN 92 4 154683 2
- WHO (2006). Guidelines for safe recreational water environments, Volume 2, swimming pools and similar environments. World Health Organization, Geneva, Switzerland ISBN 92 4 154680 8
- WHO (2003). Guidelines for safe recreational water environments, Volume 1, coastal and fresh waters. World Health Organization, Geneva, Switzerland, ISBN 92 4 154580 1
- WHO (1989). Health guidelines for the use of wastewater in agriculture and aquaculture, Technical Report Series 778, World Health Organization, Geneva